| INPUT |
Voltage |
(10~28)VDC |
| Steady DC Current |
Maximum steady state input current is less than 10ADC rms at 11V input and max. load |
| Inrush Current |
Maximum inrush current shall be less than 10A at 12Vdc input |
| Power ON LED |
Yes |
| DC Cable and Connector |
Standard length of the cable + cigarette lighter 0.3m |
| Power Efficiency |
88% minimum measured at 12Vdc input voltage, max load and include the dc cable loss |
| Input Fuse |
10A protected against power line surges and any abnormal conditions |
| OUTPUT |
DC Cable and Connector |
6A Black & Standard length of the cable 1.5M ±10cm |
| PROTECTION |
Short Circuit |
The adapter is protected when a short happened between the output terminals and shall not result in a fire hazard, any damage to this adapter, and will be normal operation automatically while the short is removed. No damage. |
| Over Power Protection |
The power supply shall be protected |
| Over Temperature |
70°C ±4 No Damage |
| Over Voltage |
The power supply shall be protected when output voltage over 27V |
| Insulation Resistance |
The resistance is more than 100MΩ at apply 500 VDC between input terminals and Case. |
| The resistance is more than 100MΩ at apply 500 VDC between input terminals and output terminals |
| ENVIRONMENT |
Cooling |
The adapter is convention cooled only |
| Temperature |
Operating: (0~45)°C / Storage: (-20 ~ 80)°C |
| Humidity |
Operating: (10~90)%RH / Storage: (5 ~ 90)%RH non-condensing |
| OTHERS |
Case Material |
PC.Class 94V-0 |
| Stability |
The adapter is unconditionally stable while operating within its normal operating specification |
| SAFETY |
CE | E16 |
|
EMC |
EN55022B, FCC Part 15B, CISPR22B, GB9254B with 4db-min. margin (Radiated emissions tested at 3 meter test distance) |
| Surge |
The adaptor EN61000-4-5 (995+A1:2001) |
| Safety |
The adapter meet EN60950&60601, UL60905&60601, IEC60950, GB4943 standard |
| WEIGHT |
1pc |
N.W.:0.235kg/pc |G.W.: 0.278kg/pc |
| PACKING |
BOX |
0.49 x 0.34 x 0.39 [m] |
| G.W.: 15kg/box |